SD-card wear
Key takeaways
Flash cells endure a finite number of write cycles, and an always-on Linux box
writes constantly — logs above all. Cheap cards have weak wear-levelling and
no spare area, so the steady drip kills them in months. The defence is tiered:
measure the write load (iostat), bound the journal
(SystemMaxUse=), move scratch data to RAM (tmpfs, log2ram), keep
deliberate data (recordings) on media built for it — high-endurance card or
SSD — and cap growth with retention policies. Then let the backup image
make the eventual failure boring.
Heat taxes performance; wear kills the whole system — the most common way an SBC appliance actually dies. The good news: write load is measurable and very compressible, and the defences stack.
Why do writes destroy flash?
A flash cell stores bits as trapped charge, and each program/erase cycle slightly damages the insulating layer — after thousands of cycles the cell no longer holds data. Controllers fight back with wear-levelling (spreading writes across all cells) and spare capacity to retire failing blocks; quality SSDs do this well, cheap SD cards barely (Storage & SD cards was the buying half of this story). Worse, flash erases in large blocks, so a tiny write can cost a full block cycle — write amplification — and a stream of tiny log lines is close to the worst case. The endgame is quiet: slowdowns, then files that won’t write, then a card stuck read-only, then no boot.
Where do all the writes come from?
On an appliance, four suspects in rough order:
- Logs. The journal, plus every chatty service, syncing line after line to disk around the clock. The classic card-killer — a misbehaving service logging an error ten times a second is a wear catastrophe and invisible until you look.
- Application data. For the scanner: recordings and the call database — deliberate writes you want, sized by your retention policy.
- Housekeeping. Package updates, temp files — modest.
- Swap. Memory pressure turning RAM shortage into disk writes; on a well-sized board it should be near-idle.
Measure before optimising — iostat (from sysstat) shows the running total:
$ sudo apt install sysstat
$ iostat -h
Device tps kB_read/s kB_wrtn/s kB_read kB_wrtn
mmcblk0 4.1 1.2k 58.3k 412.3M 19.8G
kB_wrtn since boot, divided by uptime, is your write rate. Tens of GB per day
on a cheap card is a countdown timer; a few hundred MB is years of life. Find the
culprits with a before/after diff or by watching which files grow (du -sh
/var/log/*).
How do you cut the write load?
Tiered, cheapest first:
Bound the journal. systemd’s journal happily grows to gigabytes; cap it:
# /etc/systemd/journald.conf
[Journal]
SystemMaxUse=64M
(sudo systemctl restart systemd-journald after.) You keep recent logs — which
is all an appliance needs, since monitoring
carries the long-term signal — at a fixed wear cost. Also calm any service
logging at debug verbosity in production.
Move scratch to RAM. A tmpfs is a filesystem living in memory — contents
vanish at reboot, wear cost zero. /tmp is often tmpfs already (check with
df -h /tmp); tools like log2ram go further, collecting logs in RAM and
flushing to card hourly — turning thousands of tiny writes into one big one
(write amplification working for you).
Put deliberate data on real media. Recordings and the database are the writes you want. Give them a high-endurance card at minimum — or better, move the data directory (or the whole system) to an SSD, which ends the wear conversation. And bound them with retention policies — recordings pruned after N days, database vacuumed — so growth is a flat line, not a ramp.
Rule of thumb: an appliance’s steady-state write rate should be something you have measured once and can say out loud. “About 300 MB a day, mostly recordings” is engineering; “no idea” is a countdown.
What’s the failure-day plan?
Even managed wear ends somewhere, so the last defence is attitude: the card is a
consumable. Watch for early warnings — filesystem remounting read-only,
I/O errors in dmesg, mysterious slowdowns — and keep the
backup image current, so failure day is:
new card, re-flash, restore, coffee still warm. Wear management buys years;
the backup buys indifference. An appliance wants both.
Quick check: which write source most typically kills a cheap SD card in an always-on box?
Recap
- Flash endures finite write cycles; cheap cards’ weak wear-levelling plus write amplification turns constant small writes into early death.
- Logs are the classic killer; recordings and databases are deliberate load to place and bound properly.
- Measure first (
iostat,du) — a write rate you can say out loud. - Cut in tiers:
SystemMaxUse=on the journal, tmpfs/log2ram for scratch, high-endurance card or SSD for real data, retention policies for growth. - Treat the card as a consumable: heed read-only remounts and
dmesgI/O errors, and keep the backup image current.
Next up: Watchdogs & recovery.